You maybe looking for:

Industry Portals

Static Synchronous Compensator (STATCOM)

Static Synchronous Compensator (STATCOM) is the most advanced dynamic reactive power compensation technology. The STATCOM can be regarded as a voltage source converter, which can instantly and automatically compensate the reactive power through injecting the controllable reactive current (capacitive or inductive) to improve the power factors, reduce power loss and achieve voltage stability.

Trasient voltage control

Smaller footprint

Grid friendliness

Stronger performances

IEEE

IEC

Contact Us
透明无底-智利STATCOM.png

Features

Technical Specifications

Downloads

Features

  • 01

    Trasient voltage control

    Real-time system voltage regulation of grid point of connecting to ensure both transient and steady-state voltage stability.

  • 02

    Smaller footprint

    STATCOM uses advanced power electronics such as IGBT which are much more compact and modular in design. Compared with SVC or Fixed capacitors, it doesn't need large passive components like which require more physical space. STATCOM typical footprint is approximately 30-50% smaller with the same rating.

  • 03

    Grid friendliness

    During grid system faults, STATCOM can realize voltage and frequency ride through and continue contributing trasient voltage and reactive power to support system stability.

  • 04

    Stronger performances

    STATCOM is very strong in control accuracy and speed with only ≤5ms reponse time, excellent in harmonics characteristics. The total harmonic current content of 35kV STATCOM is ≤0.6%In. STATCOM also outperform in V/I characteristics. The output capacity of STATCOM remains unchanged even at very low voltage dips. Furthermore, STATCOM can provide extensible solutions for power oscillations damping, active power filtering, imbalance control, etc.

Technical Specifications

Download

  • Rated voltage(PCC)

    66kV - 750kV

  • Rated voltage(POC)

    6kV - 66kV

  • Rated capacity

    Single Set: 0.5Mvar~400Mvar

  • Rated frequency

    50/60Hz

  • Response time

    ≤5ms

  • Type

    Cascaded H-Bridge(CHB)

  • Redundancy

    Single-phase standard N-1, redundancy up to 10%

  • Cooling method

    Airtight liquid cooling + airtight air-con

  • Layout

    Indoor / Outdoor

  • Operation modes

    Constant power factor / Constant reactive power / Voltage control mode / Voltage/Frequency ride thru / Transient voltage support

  • Extensible solutions

    Power oscillation damping / Active power filtering / Imbalance control, etc.

  • Operating temperature

    -40°C to +50°C

  • Harmonic characteristics

    Total output harmonic distortion rates ≤ 3%

  • Altitude

    5000m

Downloads

There are 1 files in total

Data Type (1)

public-contact2-bg.jpg

Tel : +021-61610502

Start your consulting journey just one step away

Contact Us