Gas-Insulated Switchgear for Compact, Reliable Substations
Sieyuan gas-insulated switchgear (GIS) brings high-voltage switching into a compact, fully enclosed design for substations where land is scarce, the environment is harsh and supply must not fail. The range covers GIS from 72.5kV to 1100kV, hybrid GIS (HGIS) up to 1100kV, 252kV and 550kV gas-insulated lines, and medium-voltage GIS and ring main units up to 40.5kV. SF6-free GIS is available at 145kV in a zero-GWP vacuum version and a low-GWP C4 gas version, and clean-air insulation is offered at medium voltage. Modular aluminium alloy enclosures combine into different main wiring schemes and are easy to expand, and most models are built to IEC, GB and DL standards.
Bays are assembled, tested and inspected in the factory and shipped as complete units, which shortens construction and commissioning on site.
Compare gas-insulated switchgear specifications
Selecting gas-insulated switchgear starts with the system voltage, then the continuous current and the short-circuit level the bays must withstand. The table lists the published ratings of each model. GIS and HGIS models of the same voltage share one row because their published ratings are identical. Wiring schemes, bay layouts and final ratings are engineered for each project.
| Model | Rated Voltage | Rated Current | Rated Short-Circuit Breaking Current | Rated Short-Time Withstand Current | Rated Peak Withstand Current | Rated Duration of Short-Circuit | |
|---|---|---|---|---|---|---|---|
| 1100kV GIS / HGIS | ZF28-1100 | 1100kV | 6300A (line bay); up to 10000A (main busbar) | 63 kA | up to 171 kA | 3 s | |
| 800kV GIS / HGIS | ZF28-800 | 800 kV | up to 6300 A | up to 63 kA | up to 171 kA | 3 s | |
| 550kV GIS / HGIS | ZF28-550 | 550 kV | up to 6300 A | up to 63 kA | up to 171 kA | 3 s | |
| 420kV GIS / HGIS | ZF28-420 | 420 kV | up to 5000 A | up to 63 kA | up to 171 kA | 3 s | |
| 252kV GIS / HGIS | ZF28-252 | 252 kV | up to 5000 A | up to 63 kA | up to 171 kA | 3 s | |
| 145kV GIS / HGIS | ZF28A-145 | 145 kV | up to 3150 A | up to 40 kA | up to 104 kA | 4 s | |
| 145kV SF₆-Free GIS / HGIS | ZF28A-145(Z) | 145 kV | up to 3150 A | up to 40 kA | up to 104 kA | 4 s | |
| ZHW58A Hybrid GIS | ZHW58A | 31.5kV, 40.5kV, 72.5kV, 145kV,170kV,252kV | Up to 4000A | Up to 50kA | Up to 50kA | Up to 135kA | 4s |
| 252/550kV Gas-Insulated Lines | GXL 28-252/550 | 252 kV/550 kV | Up to 4000 A/Up to 5000 A | Up to 63 kA | Up to 171 kA | 3 s | |
| 40.5kV Gas-Insulated Switchgear | ZF28A-40.5 | 40.5kV | Up to 4000A | Up to 40kA | Up to 40kA | Up to 104kA | 4s |
| Gas-Insulated Switchgear (cabinet) | Maximum rated voltage: 40.5 kV | Maximum rated current: 4000 A | Maximum rated short-circuit breaking current: 40 kA | 4s | |||
| SF₆-Free Gas-Insulated Switchgear | Maximum rated voltage: 40.5 kV | Maximum rated current: 2500 A | Maximum rated short-circuit breaking current: 31.5 kA | 3s | |||
| Gas-Insulated Ring Main Unit | 40.5 kV | 630 A | 25 kA | ||||
| SF₆-Free Gas-Insulated Ring Main Unit | Maximum rated voltage: 24 kV | Maximum rated current: 630 A | breaking current up to 20 kA | 3s |
Values as published on each product page; ring main unit figures are taken from the product introduction. Blank = not published.
GIS, HGIS, GIL and SF6-free: choosing the right gas-insulated technology
Each gas-insulated technology balances footprint, investment and environmental impact differently. Full GIS needs less land than HGIS or circuit-breaker-based designs, HGIS sits between GIS and air-insulated designs, gas-insulated lines replace cables and overhead lines for bulk power transfer, and SF6-free designs support carbon-neutral substations. For a side-by-side comparison with dead-tank and live-tank circuit breakers, read our DTCB vs LTCB, GIS and HGIS guide.
-
Gas-insulated switchgear (GIS)
All primary components sit inside an earthed metal enclosure, so a GIS substation typically needs only 20–30% of the land of an air-insulated one. It is essentially unaffected by the external environment, so it suits underground stations, offshore platforms and other severe sites.
-
Hybrid GIS (HGIS)
HGIS encloses the circuit breaker, disconnectors and earthing switches and uses open-type bushings on the outgoing side. Its footprint falls between GIS and air-insulated designs, its initial investment between dead-tank breakers and GIS, and it is a mainstream choice for mobile substations and fast-delivery projects.
-
Gas-insulated lines (GIL)
Large aluminium alloy tubular conductors carry up to 5000A per circuit with low reactance and low voltage drop. GIL runs through tunnels, pipe galleries, bridges or underground, with a fully earthed casing, no combustible insulation and no electromagnetic interference.
-
SF6-free designs
The 145kV SF6-free GIS comes in a zero-GWP vacuum version and a low-GWP C4 gas version, both performing no worse than conventional SF6 designs. At medium voltage, clean-air switchgear up to 40.5kV and ring main units up to 24kV reach a GWP below 1.
Why choose Sieyuan gas-insulated switchgear
Utilities, EPC contractors and industrial operators choose Sieyuan for a complete gas-insulated portfolio from one manufacturer, factory-built quality and designs that adapt to demanding sites. Every range is modular and easy to expand, so new bays or cabinets can be added as the network grows.
-
Modular and easy to expand
Standardized functional modules with standard flange dimensions combine into different main wiring schemes. Because modules are highly interchangeable, new bays can be added later with only a small impact on the substation in service.
-
Factory-assembled bays
Bays are pre-assembled, tested and inspected in the factory and shipped as complete units. At 145kV the whole bay leaves the factory and only the busbar connection is made on site, which shortens installation and commissioning.
-
Tight sealing, low partial discharge
A dual sealing structure keeps the annual gas leakage rate below 0.1%, and gas compartments are designed for maintenance-free operation. Bay partial discharge is below 3pC at 252kV, and at 145kV it is 5pC or less, which is stricter than IEC and GB require.
-
One partner for the whole substation
Bushings for GIS, SF6 gas density meters, online partial discharge monitoring, busbar protection and bay control units come from the same manufacturer, backed by 16 large-scale intelligent manufacturing plants and end-to-end support from design to commissioning.
Gas-Insulated Switchgear FAQ
Answers to the questions engineers and buyers ask most often when they specify and source gas-insulated switchgear.
What types of gas-insulated switchgear does Sieyuan manufacture?
Sieyuan manufactures four gas-insulated families. GIS covers 72.5kV to 1100kV, including 145kV, 252kV, 420kV, 550kV, 800kV and 1100kV models and 145kV SF6-free versions. HGIS is available at the same voltages, and the ZHW58A HGIS covers voltages up to 252kV. Gas-insulated lines are rated 252kV and 550kV. For distribution networks, we offer 40.5kV GIS, 40.5kV cabinet GIS with SF6 or clean air, and gas-insulated ring main units.
Is SF6-free gas-insulated switchgear available?
Yes. The 145kV SF6-free GIS comes in two versions: a vacuum version with zero GWP and a C4 gas version with a low GWP. SF6-free HGIS is also offered at 145kV. Their electrical, insulation and operational performance is no less than that of conventional SF6 GIS. At medium voltage, the SF6-free gas-insulated switchgear up to 40.5kV and the SF6-free ring main unit up to 24kV use clean air, with a GWP below 1 and an annual leakage rate of 0.05% or less.
Which standards does Sieyuan gas-insulated switchgear comply with?
Most models are built to IEC, GB and DL standards, and selected high-voltage models also list KEMA, CESI or ASTA. Medium-voltage cabinets and ring main units list IEC, GB, CE and KEMA, and the ZHW58A HGIS also lists IEEE. Gas-insulated switchgear can comply with IEC or IEEE standards according to project requirements. The 1100kV GIS enclosure is designed, manufactured and inspected to ASME standards.
How do I choose between GIS, HGIS and gas-insulated lines?
Choose GIS when land is expensive or the site is severe: it needs less land than HGIS, dead-tank or live-tank designs and is essentially unaffected by the external environment. Choose HGIS for enclosed switching with a lower initial investment and a footprint between GIS and air-insulated designs. Choose gas-insulated lines to carry bulk power at 252kV or 550kV through tunnels, pipe galleries or underground routes, without cable thermal ageing.
Can Sieyuan GIS operate in harsh environments?
Yes. The fully metal-enclosed structure isolates live parts from salt fog, condensation, dust and corrosive industrial gases. The 800kV GIS has been tested for strong sandstorms and large temperature differences, the 420kV GIS has high seismic reliability, and the 40.5kV GIS suits humid, high-altitude, extremely cold and earthquake-prone areas. Medium-voltage cabinet GIS is rated for altitudes up to 3000m, and ring main units up to 4000m in special environments.
Request a Gas-Insulated Switchgear Quote
Share your voltage level, wiring scheme, number of bays, applicable standard and delivery requirements, and a Sieyuan sales representative will get back to you.